06 - DC Trouble
ON: activates if a panel low or no battery trouble is detected, or if an HSM2204/2300 1-4 low or no
battery trouble is detected.
OFF: does not activate on DC Trouble condition.
07 - Bus Voltage
ON: activates when a system module has measured a low Aux voltage.
OFF: does not activate for a module low voltage trouble.
08 - AC Trouble
ON: activates when any system device detects an AC Failure condition.
OFF: does not activate for AC Failure conditions.
09 - Device Fault
ON: activates if one of the following device fault conditions is present:
• zone 001 – 128 fault
• keypad 01 – 16 fault
• siren 01 – 16 fault
• repeater 01 – 08 fault
• fire trouble
• CO trouble
• gas trouble
• heat trouble
• freeze trouble
• probe disconnected trouble
• self test trouble
OFF: does not activate if a device fault condition is present.
10 - Device Low Battery
ON: activates if any of the following device low battery conditions is present:
• zone 001 – 128
• keypad 01 – 16
• siren 01 – 16
• repeater 01 – 08
• user 01 – 32 (wireless keys)
OFF: does not activate if a device low battery condition is present.
11 - Device Tamper
ON: activates if any of the following device tamper conditions is present:
• zone 001 – 128
• keypad 01 – 16
• siren 01 – 16
• repeater 01 – 08