Time and Date
Use this section to program the alarm system clock.
Menu: [*][6][Master Code] > Time and Date
Keypad: [*][6][Master Code] + 01
Enter time and date using the following format: (HH:MM); (MM-DD-YY). Valid time entries are 00-23
hours, 00-59 minutes. Valid date entries are 01-12 months, 01-31 days.
Other programming options that may affect this user function:
[901]/[902] – Daylight Savings Begin/End
.
Auto-Arm/Disarm
Menu: [*][6][Master Code] > Auto Arm/Disarm
Keypad: [*][6][Master Code] + 02
With this feature enabled, the alarm system automatically arms in away mode (stay/away zones
active) or disarms at a programmed time each day (see Auto-Arm Time below). The keypad emits
three beeps to indicate the system is armed and one long beep to indicate it is disarmed.
All arming inhibit features such as latching tampers, AC inhibit, etc. also inhibit Auto Arming and
send the Auto Arm Cancellation code.
Auto-Arm Time
Menu: [*][6][Master Code] > Auto Arm Time
Keypad: [*][6][Master Code] + 03
This function is used to program the time of day each alarm system partition automatically arms.
To program an auto-arm time, select a day of the week and then key in the time. On LED/ICON
keypads, zone lights 1-7 represent Sunday to Saturday. Valid time entries are 00-23 hours: 00-59
minutes.
At the programmed time, the keypad buzzers beep for a programmed duration (for ULC
commercial burglary installations minimum duration is 10 minutes) to warn that automatic
arming is in progress. The siren also squawks once every 10 seconds during this warning period if
programmed to do so. When the warning period is complete, the exit delay elapses then the system
arms in away mode.
Auto-arming can be canceled or postponed only by entering a valid access code during the
programmed warning period. When a code is entered, the warning is silenced and auto-arming is
canceled or postponed, depending on the auto-arm postpone timer. The Auto Arm Cancellation
reporting code is transmitted (if programmed).
Note:
Auto-arming will not silence an active bell.
Note:
The Auto Arm Cancellation reporting code is also transmitted if arming is inhibited by
one of the following:
• AC / DC Inhibit Arm
• Latching System Tampers
• Zone Expander Supervisory Fault
Other programming options that may affect this function:
[151]-[158] Partition Auto-Arm/Disarm
[014] System Option 2
67
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual