Bypassing zones with a LED/ICON keypad:
1. Ensure the system is disarmed.
2. Press [*][1], then enter your access code (if required).
3. Enter the three-digit number of the zone(s) to be bypassed. The zone light turns on to
indicate that the zone is bypassed.
4. To clear a bypassed zone, repeat the above procedure. On LED keypads, the zone light turns
off to indicate that the zone is no longer bypassed.
5. To exit bypass mode and return to the ready state, press [#].
Note:
LED Keypads display the bypass status of zones 1-16 only.
Other Bypass Features:
The following features are also available on the [*][1] zone bypass menu:
Bypass Open Zones
Displays all currently open or bypassed zones. Use the scroll keys to view zones. Open zones are
indicated by an (O). To bypass a zone, press [*]. A bypassed zone is indicated by a (B).
Note:
Zones with tampers or faults must be manually bypassed.
Bypass Group
Displays a programmed group of zones (bypass group) commonly bypassed. Press [*] to bypass all
zones in the group.
Program Bypass Group
To program a bypass group, bypass all desired zones then select Bypass Options; Program Bypass
Group. The selected zones are saved to the bypass group. When finished, press [#] to exit.
In order to program a bypass group, a master or supervisor code with access to the appropriate
partition must be used.
Bypass Recall
Press [*] while in this menu to bypass the same group of zones that were bypassed the last time
the partition was armed.
Clear Bypasses
Press [*] to clear all bypasses.
Shortcuts from the [*][1] base menu:
991 = bypass group
995 = program group 1
998 = bypass open zones
999 = bypass recall
000 = clear group
When The Alarm System is Armed
When the system is armed, pressing [*][1] toggles between stay, away or night arming. If a night
zone is on the system, pressing [*][1] either prompts the user for an access code if required, or
sounds an acknowledgment tone and changes the arming mode.
Note:
If section [022], Option 5 [Stay/Away Toggle] is on, the system does not change from
Away to Stay mode.
57
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual