Late to Open Time
Menu: [*][6][Master Code] > Late To Open Time
Keypad: [*][6][Master Code] + 10
This function is used to program the time of day the partition must be disarmed by when the Late
to Open option is enabled. A separate time can be programmed for each day of the week. Valid
data entries are 00:00 - 23:59. 99:99 disables the late to open feature for the selected day.
Select a day of the week by scrolling while in the Late to Open menu, or by using keys 1-7 to select
Sunday to Saturday respectively.
SMS Programming
Menu: [*][6][Master Code] > SMS Programming
Keypad: [*][6][Master Code] + 11
This function is used to program up to 8 phone numbers for SMS command access and
communications. SMS enables users to send commands to the alarm panel via a mobile device.
Leave an SMS phone number blank to disable it. SMS phone numbers are not related to phone
numbers used to dial the central monitoring station.
Note:
If SMS command and control features are disabled then this function is not accessible.
See the alternate communicator installation manual for more information.
Brightness Control
Menu: [*][6][Master Code] > Brightness Control
Keypad: [*][6][Master Code] + 12
This function is used to change the brightness level of keypad display backlighting. Use the scroll
keys to increase and decrease brightness or enter a value from 00 to 15. Selecting 00 turns off
keypad backlighting.
Contrast Control
Menu: [*][6][Master Code] > Contrast
Keypad: [*][6][Master Code] + 13
This function is used to change the contrast level of keypad displays. Use the scroll keys to increase
and decrease contrast or enter a value from 00 to 15. Selecting 00 turns off keypad contrast.
Buzzer Control
Menu: [*][6][Master Code] > Buzzer Control
Keypad: [*][6][Master Code] + 14
This function is used to change the volume level of keypad buzzers.
Use the scroll keys (LCD keypads) or the [*] key (LED/ICON keypads) to increase and decrease
volume or key in a value from 00 to 15. Selecting 00 turns off the keypad buzzer.
Note:
For UL/ULC listed installations, do not turn off the keypad sounder.
Authorize Firmware Update
Menu: [*][6][Master Code] > Authorize Update
Keypad: [*][6][Master Code] + 17
69
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual