Note:
For UL listed installations, this option must be disabled.
OFF: [*][8] installer programming is not available when any partition on the system is armed. All
partitions must be disarmed and the siren must be off before [*][8] is accessible.
4 - Remote Reset
ON: If an alarm occurs on a burglary zone, the system is locked out after disarming. It remains
locked until a 5-digit reset code, provided by the installer/central station, is keyed in. If a duress
code is used to disarm the partition, the system is not locked out.
In the disarmed state, only Audible 24 Hour Burglary zones, Audible 24 Hour Latching Tamper
zones, and Audible 24 Hour zone on PGM 2 cause lockout.
To obtain the reset code, the user must provide a corresponding system lock code, displayed on the
keypad when one of the following conditions occurs:
• the system has been disarmed (Duress Code excluded)
• the bell has timed out (24Hr zones)
• an access code has been entered (24Hr zones)
On an LCD keypad, the message “REMOTE RESET RQD” is displayed on the top line and “CODE”
along with the actual code is displayed across the bottom line.
On an LED keypad, the reset number is scrolled across the screen.
While the system is locked out, the only options available are [*][3], [*][6], [*][7], and [*][8].
Accessing [*][8] Installer Programming unlocks the alarm system. The system continues to function
(alarms, tampers, etc) while the system is locked out. Lock out follows both transmission and bell
delays.
OFF: The system is not locked out after an alarm occurs.
Note:
Not for use with UL/ULC listed installations.
5 - Engineer’s Reset (EU)
ON: If the alarm system has gone into alarm during the previous armed period, or if a 24-hour
alarm has occurred (armed or disarmed), the system cannot be armed (Ready light OFF) until
Installer Programming is entered or Engineer’s Reset is performed via DLS. “Reset Required” is
displayed on the keypad. This feature applies to tampers and faults in both armed and disarmed
states and does not apply to module tampers, system supervisories, zone expander alarms or PGM
2 input alarms.
Note:
If Engineer’s Reset is triggered during exit delay, the system still arms. Troubles cannot
be overridden while Engineer’s Reset is enabled.
OFF: The system does not require Engineer’s Reset or to be placed into Installer Programming in
order to arm the alarm system after an alarm.
6 - Keyswitch Disarming During Entry Delay
ON: Keyswitches, proximity tags and wireless keys disarm the alarm system only if an entry delay is
active.
OFF: Keyswitches, proximity tags and wireless keys disarm the alarm system regardless of entry
delay.
7 - Installer Access and DLS
ON: The user must enter [*][6][access code][05] before the installer can access Installer
Programming by DLS or via the keypad ([*][8]).
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual