[04] Receiver 4
[310] Account Codes
These programming sections are used to set the system and partition account codes.
[000] System Account Code
The system account code is used to identify the alarm system when communicating system events
to the central station. The system account code can be either 4 or 6 digits long. Program a 6-digit
code only when using the SIA reporting format. SIA uses this account code for all partitions and
system events. All other reporting formats use a 4-digit system account code to report system
maintenance (e.g., low battery, zone fault) and test transmission events. To program a 4-digit code,
add FF to the last two digits.
[001]-[008] Partition Account Codes
Use these sections to program account codes for each partition.
When using formats other than SIA, these account codes identify the alarm system to the central
station when communicating partition-specific events.
Note:
The system will not communicate if the account code is not programmed. When this
condition occurs, Account Code Not Programmed is briefly displayed on the keypad when
exiting Installer Programming mode.
Note:
If no phone numbers are programmed, the error message does not occur.
[311]-[318] Partition Call Directions
Use this programming option to select the central station receivers that partition events are
communicated to. Call directions can be programmed for each partition. Each event can be sent to
one of four receivers.
[001] Alarm/ Restore
These options control which receiver paths are enabled for Partition 1-8 Alarm and Restore event
reporting codes.
To assign an event to a receiver, select one of the following options:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[002] Tampers (Including System Tampers)/ Restore
These options control which receiver paths are enabled for Partition 1-8 Tamper and Restore event
reporting codes.
To assign an event to a receiver, select one of the following options:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[003] Openings/ Closing
These options control which receiver paths are enabled for Partition 1-8 Opening and Closing event
reporting codes. To assign an event to a receiver, select one of the following options:
[01] Receiver 1
139
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual