Field
Value Range
Description
B1 BER Threshold-Crossing
Generated
Yes, No
Default value: No
The
B1 BER Threshold-
Crossing Generated
parameter is used to specify
whether a B1 BER threshold-
crossing alarm is a condition
for triggering clock source
switching. B1 BER
Threshold-Crossing alarm is
an index for measuring the
performance of clock source
signals.
You can click
to display the
detailed information.
RLOS, RLOF and OOF
Alarms Generated
Yes
Displays whether the
switching condition is
enabled. If the R_LOS,
R_LOF, or OOF alarm is
reported, the NE considers
that the corresponding clock
source is faulty.
By default, this parameter is
set to yes and cannot be
changed.
CV Threshold-Crossing
Generated
Yes, No
Sets the switching condition
enable status. When CV
threshold-crossing occurs in
the NE, the NE thinks that the
corresponding clock source
fails.
CV Threshold
-
Displays the CV threshold.
B2-EXC Alarm Generated
Yes, No
Default value: No
The
B2-EXC Alarm
Generated
parameter is used
to specify whether a B2-EXC
alarm is a condition for
triggering clock source
switching. B2-EXC alarm is
an index for measuring the
performance of clock source
signals.
You can click
to display
the detailed information.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
2 Creating the Network
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-29