Parame
ter
Value in This Example Description
Scrambl
e
VCTRUNK1:
Scrambling mode [X43
+1]
In this example, this parameter adopts the
default value
Scrambling mode [X43+1]
.
Scramble
of the VCTRUNKs on the
Ethernet boards of the interconnected
equipment at both ends must be set to the
same value.
Check
Field
Length
VCTRUNK1: FCS32
In this example, this parameter adopts the
default value
FCS32
.
Check Field Length
of the VCTRUNKs on the Ethernet boards of
the interconnected equipment at both ends
must be set to the same value.
FCS
Calculat
ed Bit
Sequenc
e
VCTRUNK1: Big endian When
Mapping Protocol
is set to
GFP
,
FCS
Calculated Bit Sequence
is set to
Big
endian
.
FCS Calculated Bit Sequence
of
the VCTRUNKs on the Ethernet boards of
the interconnected equipment at both ends
must be set to the same value.
Set
Inverse
Value
for CRC
VCTRUNK1: -
When
Mapping Protocol
is set to
GFP
, this
parameter is valid and adopts the default
value
-
.
Set Inverse Value for CRC
of the
VCTRUNKs on the Ethernet boards of the
interconnected equipment at both ends must
be set to the same value.
l
Click the
Bound Path
tab. Click the
Configuration
button. Set the following
parameters in the
Bound Path Configuration
dialog box that is displayed. Then, click
Apply
.
User
Parameter Value in
This
Example
Description
User
A1
←
→
user
A2
Configurab
le Ports
VCTRUN
K1 (3-
EGT1)
As shown in
, VCTRUNK1 of the
3-EGT1 board is used by the service between
user A1 and user A2.
Avai
lable
Bou
nd
Path
s
Lev
el
VC12-xv
The service between user A1 and user A2 uses
a 10 Mbit/s bandwidth. Hence, five VC-12s
need to be bound.
For the method of computing the bound
timeslots based on the service bandwidth, see
6.3 Ethernet Service Bandwidths Carried
by VCTRUNKs of Ethernet Boards
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-38
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)