7.116 2M Phase-Locked Source Fail Condition
Description
The
2M Phase-Locked Source Fail Condition
parameter is used to set the failure condition of
the 2M phase-locked source.
Impact on the System
The system running is not affected.
Values
Value Range
Default Value
No Failure Condition, AIS,
LOF, AIS OR LOF
No Failure Condition
The following table lists the description of each value.
Value
Description
No Failure Condition
Indicates that no failure condition is set. The 2M phase-lock
source remains valid when an AIS or LOF alarm of the
external clock signal occurs.
AIS
Indicates that the failure condition is set to AIS. The 2M
phase-lock source becomes invalid when an AIS alarm of
external clock signal occurs.
LOF
Indicates that the failure condition is set to an LOF alarm. The
2M phase-lock source becomes invalid when an LOF alarm
of external clock signal occurs.
AIS OR LOF
Indicates that the failure condition is set to an AIS alarm or
LOF alarm. The 2M phase-lock source becomes invalid when
an AIS or LOF alarm of external clock signal occurs.
Configuration Guidelines
Failure condition can be set as required.
Relationship with Other Parameters
None.
7 List of Parameters
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
7-94
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)