Parameter
Value in
This
Example
Description
Sink Slot
1-SL1D-1
(SDH-1)
In this example, the SL1D board in slot 1 is configured
as the sink line board. See
.
Sink VC4
VC4-1
In this example, the services require five VC-12s.
Sink
VC4
is set to
VC4-1
, because a VC-4 contains 63
VC-12s.
Sink
Timeslot
Range(e.g.
1,3-6)
1-5
The total capacity of the services is 5xE1 according to
the plan. Hence,
Sink Timeslot Range(e.g.1,3-6)
is set
to
1-5
.
Activate
Immediately
Yes
-
2.
Configure unidirectional pass-through services on NE4.
Parameter
Value in
This
Example
Description
Level
VC12
In this example, E1 services are configured. Hence,
Level
of the E1 services is set to
VC12
.
Direction
Unidirection
al
In this example, the services are transmitted and received
on different paths. That is, the services are unidirectional
services. Hence,
Direction
of the services is set to
Unidirectional
.
Source Slot
1-SL1D-2
(SDH-2)
In this example, the SL1D board in slot 1 is configured
as the source line board. See
.
Source VC4
VC4-1
In this example, the services require five VC-12s.
Source VC4
is set to
VC4-1
, because a VC-4 contains
63 VC-12s.
Source
Timeslot
Range(e.g.
1,3-6)
1-5
The total capacity of the services is 5xE1 according to
the plan. Hence,
Source Timeslot Range(e.g.1,3-6)
is
set to
1-5
.
Sink Slot
1-SL1D-1
(SDH-1)
In this example, the SL1D board in slot 1 is configured
as the sink line board. See
.
Sink VC4
VC4-1
In this example, the services require five VC-12s.
Sink
VC4
is set to
VC4-1
, because a VC-4 contains 63
VC-12s.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
3 Configuring SDH Services
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-33