l
Click the
Basic Attributes
tab. After setting the parameters, click
Apply
.
Parame
ter
Value in This Example Description
Enabled
/
Disable
d
PORT1: Enabled
In this example, PORT1 carries the services
and is set to
Enabled
.
Workin
g Mode
PORT1: Auto-
Negotiation
The Ethernet service access equipment of
user F1 supports the auto-negotiation mode.
In this example,
Working Mode
is set to
Auto-Negotiation
.
Maximu
m
Frame
Length
PORT1: 1522
Generally, this parameter adopts the default
value
1522
.
MAC
Loopba
ck
PORT1: Non-Loopback
The MAC loopback setting is used for fault
diagnosis. In this example,
MAC
Loopback
is set to
Non-Loopback
.
PHY
Loopba
ck
PORT1: Non-Loopback
The PHY loopback setting is used for fault
diagnosis. In this example,
PHY Loopback
is set to
Non-Loopback
.
l
Click the
Flow Control
tab. The parameters in the
Flow Control
tab page adopt the
default values.
l
Click the
TAG Attributes
tab. After setting the parameters, click
Apply
.
Parame
ter
Value in This Example Description
Entry
Detectio
n
PORT1: Enabled
If the packets of user F1 carry VLAN tags,
you need to enable the entry detection
function to detect the VLAN tags of packets.
In this example,
Entry Detection
is set to
Enabled
.
TAG
PORT1: Tag Aware
The service access equipment of user F1
supports VLANs and the transmitted data
frames carry VLAN tags. In this example,
Tag
is set to
Tag Aware
for PORT1.
Default
VLAN
ID
-
When
TAG
is set to
Tag Aware
, you need
not set
Default VLAN ID
.
VLAN
Priority
-
When
TAG
is set to
Tag Aware
, you need
not set
VLAN Priority
.
OptiX OSN 550 Multi-Service CPE Optical Transmission