User
Paramete
r
Value in
This
Example
Description
Sink VC4
VC4-1
In this example, VC4-1 is specified as the
VC-4 timeslot of the Ethernet service on the
line board.
Sink
Timeslot
Range(e.g.
1,3-6)
6-15
The value range of the sink timeslot can be
the same as or different from the value
range of the source timeslot. The number of
source timeslots must be, however, the
same as the number of sink timeslots. For
example, if the source timeslots are 10
VC-12s, the sink timeslots must be 10
VC-12s.
Activate
Immediatel
y
Yes
-
Step 2
Configure the pass-through services of user A1 and user B1 on NE2.
1.
Click
. Select NE2 in the
Navigation Tree
that is displayed. Then, click
OK
.
2.
In the NE Explorer, select NE2 and then choose
Configuration
>
SDH Service
Configuration
from the Function Tree.
3.
Click
Create
on the lower-right pane to display the
Create SDH Service
dialog box. Set
the parameters as follows.
Parameter Value in
This
Example
Description
Level
VC12
The SDH service of NE1, which passes through NE2, is
at the VC-12 level.
Service
Direction
Bidirectional
As shown in
NE2 is a bidirectional service.
Source Slot 5-SL4D-1
(SDH-1)
As shown in
transmitted from 5-SL4D-1(SDH-1) to 5-SL4D-2
(SDH-2). In this example,
Source Slot
is set to
5-SL4D-1
(SDH-1)
.
Source
VC4
VC4-1
VC4-1 is allocated to the service from NE1 to NE2.
Source
Timeslot
Range(e.g.
1,3-6)
1-15
The service between user A1 and user B1 uses timeslots
1-15.
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-42
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)