Step 2
Configure the EPL services on NE2 and NE4.
NOTE
The Ethernet services of NE2 and NE4 are point-to-point transparent transmission EPL services. See
Configuring EPL Services on an Ethernet Transparent Transmission Board
Step 3
Check whether the services are configured correctly. For the operation procedures, see Testing
Ethernet Service Channels.
l
Before testing the service connectivity between F1 and F2, set
TAG
to
Access
and set
Default
VLAN ID
to
1
for PORT1 and VCTRUNK1, which receive the services of F1 and F2
respectively, on the EFS8 board.
l
Before testing the service connectivity between F1 and F3, set
TAG
to
Access
and
Default
VLAN ID
to
1
for PORT1 and VCTRUNK2, which receive the services of F1 and F3
respectively, on the EFS8 board.
NOTE
After the test, change the modified parameter values to the values specified in the service configuration.
Step 4
Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 5
Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and thus need to be deleted, see
4.9 Configuring EVPLAN Services (IEEE 802.1q Bridge)
The EVPLAN service (IEEE 802.1q bridge) provides an LAN solution for multipoint-to-
multipoint convergence. This service applies in cases where user-side data communication
equipment connected to the transmission network does not support VLANs or where the VLAN
planning is open to the network operator.
4.9.2 Signal Flow and Timeslot Allocation
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-96
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)