Parameter
Value in
This
Example
Description
Source VC4
VC4-1
In this example, the services require five VC-12s.
Source VC4
is set to
VC4-1
, because a VC-4 contains
63 VC-12s.
Source
Timeslot
Range(e.g.
1,3-6)
1-5
The total capacity of the services is 5xE1 according to
the plan. Hence,
Source Timeslot Range(e.g.1,3-6)
is
set to
1-5
.
Sink Slot
3-SP3D
In this example, the SP3D board in slot 3 is configured
as the sink tributary board for the unidirectional services
from NE1 to NE3. See
.
Sink VC4
-
-
Sink
Timeslot
Range(e.g.
1,3-6)
1-5
The total capacity of the services is 5xE1 according to
the planning. Hence,
Sink Timeslot Range(e.g.1,3-6)
is
set to
1-5
.
Activate
Immediately
Yes
-
Step 2
Configure unidirectional services from NE3 to NE1.
To configure unidirectional services from NE3 to NE1, refer to
.
1.
Configure SDH services on the source NE (NE3).
Parameter
Value in
This
Example
Description
Level
VC12
In this example, E1 services are configured. Hence,
Level
of the E1 services is set to
VC12
.
Direction
Unidirection
al
In this example, the services are transmitted and received
on different paths. That is, the services are unidirectional
services. Hence,
Direction
of the services is set to
Unidirectional
.
Source Slot
3-SP3D
In this example, the SP3D board in slot 3 is configured
as the source tributary board for the unidirectional
services from NE3 to NE1. See
Source
Timeslot
Range(e.g.
1,3-6)
1-5
The total capacity of the services is 5xE1 according to
the plan. Hence,
Source Timeslot Range(e.g.1,3-6)
is
set to
1-5
.
3 Configuring SDH Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
3-32
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)