l
In the NE Explorer, select the EFS8 board, and then choose
Configuration
>
Ethernet
Service
>
Ethernet Line Service
from the Function Tree.
l
Click
New
on the lower-right pane to display the
Create Ethernet Line Service
window. Set the following parameters and then click
OK
. The
Operation Result
dialog
box is displayed, indicating that the operation is successful. Click
Close
.
User
Parameter
Value in
This
Example
Description
User D1
←→
user
D2
Service
Type
EPL
The service between user D1 and user D2 is a
point-to-point EVPL service.
Service
Direction
Bidirection
al
The service between user D1 and user D2 is a
bidirectional service.
Source Port
PORT1
When creating the bidirectional Ethernet
service from a PORT to a VCTRUNK, it is
recommended that you use a specific PORT as
the source port. In this example, PORT1 is the
external port used by the service between user
D1 and user D2.
Source C-
VLAN (e.g.
1, 3-6)
100
According to the plan, the VLAN ID is set to
100 on the transmission network side for
Ethernet service between user D1 and user D2.
Sink Port
VCTRUN
K1
When creating the bidirectional Ethernet
service from a PORT to a VCTRUNK, it is
recommended that you use a specific
VCTRUNK as the sink port. In this example,
VCTRUNK1 is the internal port used by the
service between user D1 and user D2.
Sink C-
VLAN (e.g.
1, 3-6)
100
According to the plan, the VLAN ID is set to
100 on the transmission network side for
Ethernet services between user D1 and user D2.
User E1
←→
user
E2
Service
Type
EPL
The service between user E1 and E2 is a point-
to-point Ethernet private line service.
Service
Direction
Bidirection
al
The service between user E1 and user E2 is a
bidirectional service.
Source Port
PORT2
When creating the bidirectional Ethernet
service from a PORT to a VCTRUNK, it is
recommended that you use a specific PORT as
the source port. In this example, PORT2 is the
external port used by the service between user
E1 and user E2.
Source C-
VLAN (e.g.
1, 3-6)
200
According to the plan, the VLAN ID is set to
200 on the transmission network side for
Ethernet service between user E1 and user E2.
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-80
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)