User
Paramete
r
Value in
This
Example
Description
User C1
←→
user C2
Level
VC12
The timeslots bound with the service
between user C1 and user C2 is at the VC-12
level. The service level must be consistent
with the level of the paths bound with the
VCTRUNK.
Service
Direction
Bidirectiona
l
The service between user C1 and user C2 is
a bidirectional service.
Source Slot 4-EFS8-1
(SDH-1)
When you create a bidirectional SDH
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the Ethernet board as the source slot.
Source
VC4
VC4-4
The value range of
Source VC4
is
consistent with the value range of
Available Resources
, which is set for the
paths bound with VCTRUNK1. In this
example,
Source VC4
is set to
VC4-4
.
Source
Timeslot
Range(e.g.
1,3-6)
1-10
The value range of the source timeslots is
consistent with the value range of
Available Timeslots
, which is set for the
paths bound with VCTRUNK1. In this
example, the value range of
Available
Timeslots
is from VC12-1 to VC12-10.
Sink Slot
6-SL4D-1
(SDH-1)
When you create a bidirectional SDH
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the line board as the sink slot.
Sink VC4
VC4-1
In this example, VC4-1 is specified as the
VC-4 timeslot of the Ethernet service on the
line board.
Sink
Timeslot
Range(e.g.
1,3-6)
1-10
The value range of the sink timeslots can be
the same as or different from the value
range of the source timeslots. The number
of source timeslots must be, however, the
same as the number of sink timeslots. For
example, if the source timeslots are ten
VC-12s, the sink timeslots must be ten
VC-12s.
Activate
Immediatel
y
Yes
-
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-70
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)