User
Paramete
r
Value in
This
Example
Description
Sink
Timeslot
Range(e.g.
1,3-6)
6-15
The value range of the sink timeslots can be
the same as or different from the value
range of the source timeslots. The number
of source timeslots must be, however, the
same as the number of sink timeslots. For
example, if the source timeslots are 10
VC-12s, the sink timeslots must be 10
VC-12s.
Activate
Immediatel
y
Yes
-
Step 2
Configure the EPL services for users A1 and B1 on NE2.
1.
Click
. Select NE2 in the
Navigation Tree
that is displayed. Then, click
OK
.
2.
In the NE Explorer, select NE2, and then choose
Configuration
>
SDH Service
Configuration
from the Function Tree.
3.
Click
Create
on the lower-right pane to display the
Create SDH Service
dialog box. Set
the parameters as follows.
Parameter Value in
This
Example
Description
Level
VC12
The SDH service of NE1, which passes through NE2, is
at the VC-12 level.
Service
Direction
Bidirectional
As shown in
NE2 is a bidirectional service.
Source Slot 6-SL4D-1
(SDH-1)
As shown in
transmitted from 6-SL4D-1(SDH-1) to 6-SL4D-2
(SDH-2). In this example,
Source Slot
is set to
6-SL4D-1
(SDH-1)
.
Source
VC4
VC4-1
VC4-1 is allocated to the service from NE1 to NE2.
Source
Timeslot
Range(e.g.
1,3-6)
1-15
The service between user A1 and user B1 uses timeslots
1-15.
Sink Slot
6-SL4D-2
(SDH-2)
As shown in
transmitted from 6-SL4D-1(SDH-1) to 6-SL4D-2
(SDH-2). In this example,
Sink Slot
is set to
6-SL4D-2
(SDH-2)
.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4 Configuring Ethernet Services
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4-55