NOTE
The Ethernet services of NE2 and NE4 are point-to-point transparent transmission services. See
Configuring EPL Services on an Ethernet Transparent Transmission Board
Step 3
Check whether the services are configured correctly. For the operation procedures, see Testing
Ethernet Service Channels.
l
Before testing the service connectivity between headquarters C1 and branch C2, set
TAG
of
PORT1 on the EFS8 board to
Access
and
Default VLAN ID
to
100
.
l
Before testing the service connectivity between headquarters C1 and branch C3, set
TAG
of
PORT1 on the EFS8 board to
Access
and
Default VLAN ID
to
200
.
NOTE
After the test, change the modified parameter values to the values specified in the service configuration.
Step 4
Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 5
Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and thus need to be deleted, see
.
4.7 Configuring VCTRUNK-Shared EVPL (VLAN) Services
When the data of multiple users without VLAN tags sent to a transmission network is transmitted
on the same VCTRUNK, the VCTRUNK-shared EVPL (VLAN) service is used to isolate the
data by adding VLAN tags. In this way, the bandwidth is shared on the SDH side.
4.7.2 Signal Flow and Timeslot Allocation
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-72