Parame
ter
Value in This Example Description
Enabled
/
Disable
d
PORT1: Enabled
The service of user C1 occupies PORT1. In
this example,
Enabled/Disabled
is set to
Enable
.
Workin
g Mode
PORT1: Auto-
Negotiation
The Ethernet service access equipment of
user C1 supports the auto-negotiation mode.
In this example,
Working Mode
is set to
Auto-Negotiation
.
Maximu
m
Frame
Length
PORT1: 1522
Generally, this parameter adopts the default
value
1522
.
MAC
Loopba
ck
PORT1: Non-Loopback
The MAC loopback setting is used for fault
diagnosis. In this example,
MAC
Loopback
is set to
Non-Loopback
.
PHY
Loopba
ck
PORT1: Non-Loopback
The PHY loopback setting is used for fault
diagnosis. In this example,
PHY Loopback
is set to
Non-Loopback
.
l
Click the
Flow Control
tab. The parameters in the
Flow Control
tab page adopt the
default values.
l
Click the
TAG Attributes
tab. After setting the parameters, click
Apply
.
Parame
ter
Value in This Example Description
TAG
PORT1: Tag Aware
When the port is set to
Tag Aware
, all data
frames transmitted and received at the port
must have VLAN tags. In this example,
TAG
is set to
Tag Aware
.
Default
VLAN
ID
-
When
TAG
is set to
Tag Aware
, you need
not set
Default VLAN ID
.
VLAN
Priority
-
When
TAG
is set to
Tag Aware
, you need
not set
VLAN Priority
.
Entry
Detectio
n
PORT1: Enabled
The equipment of user C1 supports VLANs.
Hence, the entry detection function must be
enabled to check the VLAN tag. In this way,
the user data frames with different VLAN
tags can be distinguished at one port. In this
example,
Entry Detection
of PORT1 is set
to
Enabled
.
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-64
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)