Field
Value
Description
Assigned by VC4
Selected, Deselected
Indicates that different VC-4s
correspond to different
protection subnetworks. You
can group VC-4s in the
optical fiber into different
protection subnets to protect
virtual optical channels. This
means that certain VC-4s in
the fiber can be allocated to a
protection subnetwork. For
example, in the case of an
STM-16 fiber, the former four
VC-4s can be allocated for an
STM-4 MSP, and the
following four VC-4s can be
allocated for channel
protection.
NOTE
For LMSP,
Assigned by VC4
is
not supported.
Node
For example: NE70
Displays the selected NE.
Link
For example: NE140-NE141
Ring 1
Displays the fiber link of the
protection subnetwork.
Physical Information
For example: 1-SL1Q-1
(SDH-1)-1-SL1Q-2(SDH-1)
Displays the line board
resource used by the fiber
link.
VC4
For example: 1 to 4
If
Assigned by VC4
is
selected in Step 1, you can
specify the VC-4 resource
used by the protection
subnetwork in Step 2.
Subnet Name
For example: Two-fiber
bidirectional multiplex
section shared protection
ring_1
Displays the name of the
protection subnetwork.
Subnet Type
2f_MS SPRing, 2f_MS
DPRing, 1+1 Linear MSP,
M:N Linear MSP,
Unprotected Ring,
Unprotected Chain
Displays the type of the
protection subnetwork.
WTR Time (s)
For example: 600
Displays the switching WTR
time of the protection
subnetwork.
Revertive Mode
Non-Revertive, Revertive
Displays the revertive mode
of the protection subnetwork.