Field
Value
Description
WTR Time (s)
Example: 600
Specifies the wait-to-restore
(WTR) time of the NE.
When the time after the
former working channel is
restored to normal reaches the
set WTR time, a revertive
switching occurs. This field is
available only when
Revertive Mode
is set to
Revertive
.
Hold-Off Time (100 ms)
0 to 100
Default: 0
Specifies the hold-off time of
the NE.
If
Hold-Off Time (100 ms)
is
set to
0
, you do not need to set
a specific hold-off time.
Source Board
Example: 1-SL1D-1
(SDH-1)
Displays the slot ID, board
name, port number, and port
name at the source end.
Sink Board
Example: 3-SP3D
Displays the slot ID, board
name, port number, and port
name at the sink end.
Source VC4
Example: VC4-1
Specifies the VC-4 timeslot at
the source end.
One VC-4 timeslot can
contain a maximum of 63
VC-12 timeslots.
Sink VC4
-
Specifies the VC-4 timeslot at
the sink end.
Source Timeslot Range(eg.1,
3-6)
Example: 1-5
Specifies the timeslot range at
the source end.
3.11.2 Configuring the Multiplex Section Protection
You need to set the necessary parameters when configuring the multiplex section protection
(MSP).
lists the parameters for configuring the MSP.