Table 3-2
Parameters for configuring the MSP
Field
Value
Description
Name
For Example: two-fiber
bidirectional multiplex
section shared protection
ring_1
Indicates the name of the
protection subnetwork. Th
name of a new protection
subnetwork is automatically
generated. You can rename
the protection subnetwork
according to the
requirements.
Level
If
Assigned by VC4
is not
selected, the values are
STM-1, STM-4, STM-16,
STM-64, and STM-256.
If
Assigned by VC4
is
selected, the values are
STM-2, STM-4, STM-6, ...,
STM-254, and STM-256.
NOTE
l
The OptiX OSN 550
supports only STM-1,
STM-4 and STM-16
levels.
l
For LMSP,
Assigned by
VC4
is not supported.
Indicates the new capacity
level of a protection
subnetwork. The new
capacity level of a protection
subnetwork must be the same
as the transmission rate of the
line boards that form the
protection subnetwork.
CAUTION
When selecting an incorrect
capacity level, you fail to create
a protection subnetwork.
Resource Sharing
-
Resource sharing indicates
that two protection
subnetworks can share one
physical resource. If multiple
protection subnetworks are
created on a fiber, the second
and later protection
subnetworks share the
resources on the fiber.
NOTE
The OptiX OSN 550 does not
support this parameter.
3 Configuring SDH Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
3-70
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)