Field
Value Range
Description
Clock Source WTR Time
0-12
Default value: 5
The
Clock Source WTR
Time
parameter is used to
specify the wait-to-restore
(WTR) time when the
Higher Priority Clock
Source Reversion Mode
parameter is set to
Auto-
Revertive
. When a clock
source is restored to its valid
status, the system does not
regard it as a valid source
immediately but verifies the
validity of the clock source in
a specific period of time. The
system regards the clock
source as a valid source only
if the clock source remains
valid during the specific
period of time. This specific
period of time is called the
WTR time of the clock
source.
You can click
to
display the detailed
information.
Clock Source
For example: Internal Clock
Source
Displays the name of the
clock source.
AIS Alarm Generated
Yes, No
Default value: No
The
AIS Alarm Generated
parameter is used to specify
whether an AIS alarm is a
condition for triggering the
switching of clock sources.
You can click
to display
the detailed information.