7.119 AIS Alarm Generated
Description
The
AIS Alarm Generated
parameter is used to specify whether an AIS alarm is a condition
for triggering the switching of clock sources.
Impact on the System
The system running is not affected.
Values
Value Range
Default Value
Yes, No
No
The following table lists the description of each value.
Value
Description
Yes
Indicates that an AIS alarm is the sufficient condition to
trigger clock source switching.
No
Indicates that an AIS alarm is not a condition for triggering
clock source switching.
Configuration Guidelines
It is recommended to set the AIS alarm as the condition for triggering clock source switching
in actual application to ensure system performance.
Relationship with Other Parameters
None.