7.120 B1 BER Threshold-Crossing Generated
Description
The
B1 BER Threshold-Crossing Generated
parameter is used to specify whether a B1 BER
threshold-crossing alarm is a condition for triggering clock source switching. B1 BER
Threshold-Crossing alarm is an index for measuring the performance of clock source signals.
Impact on the System
The system running is not affected.
Values
Value Range
Default Value
Yes, No
No
The following table lists the description of each value.
Value
Description
Yes
Indicates that a B1 BER threshold-crossing alarm is the
sufficient condition for triggering clock source switching.
No
Indicates that a B1 BER threshold-crossing alarm is not the
condition for triggering clock source switching.
Configuration Guidelines
A B1 BER threshold-crossing alarm indicates that the transmitted signal and the clock in the
signal are being interfered. Therefore, this parameter can be set as a condition for triggering
clock source switching in actual application to ensure system performance.
Relationship with Other Parameters
None.
Related Information
None.
7 List of Parameters
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
7-98
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)