Ver.3
−
−
−
−
109
Parameter group P
Register
No.
Function name
Function
code
R/W
Monitoring and setting items
Data
resolution
1601h
Operation mode on expansion card
1 error
P001
R/W
0 (tripping), 1 (continuing operation)
-
1602h
(Reserved)
-
-
-
-
1603h
[EA] terminal selection
P003
R/W
00 (Speed reference, incl. PID)
01 (Encoder feedback)
02 (Extended terminal for EzSQ)
1604h
Pulse train input mode for feedback
P004
R/W
00 (Single-phase pulse [EA])
01 (2-phase pulse [90° difference] 1 ([EA] and [EB]))
02 (2-phase pulse [90° difference] 2 ([EA] and [EB]))
03 (Single-phase pulse [EA] and direction signal [EB])
1605h to
160Ah
(Reserved)
-
-
-
-
160Bh
Encoder pulse-per-revolution (PPR)
setting
P011
R/W
32 to 1024
1
160Ch
Simple positioning selection
P012
R/W
00 (simple positioning deactivated)
02 (simple positioning activated)
-
160Dh
(Reserved)
-
-
-
-
160Eh
Creep pulse ratio
*2
P014
R/W
0 to 4000
0.1[%]
160Fh
Creep speed
P015
R/W
"start frequency" to 1000
0.01 [Hz]
1610h
(Reserved)
-
-
-
-
1611h
Positioning completion range
*2
P017
R/W
0 to 10000
1[pulse]
1612h to
1619h
(Reserved)
-
-
-
-
161Ah
Over-speed error detection level
P026
R/W
0 to 1500
0.1 [%]
161Bh
Speed deviation error detection
level
P027
R/W
0 to 12000
0.01 [Hz]
161Ch to
161Eh
(Reserved)
-
-
-
-
161Fh
Accel/decel time input selection
P031
R/W
0 (digital operator), 3 (easy sequence)
-
1620h
(Reserved)
-
-
-
-
1621h
Torque command input selection
P033
R/W
0 (O terminal),
1 (OI terminal),
3 (digital operator), 06 (Option)
-
1622h
Torque command setting
P034
R/W
0 to 200
1 [%]
1623h
(Reserved)
-
-
-
-
1624h
Torque bias mode
P036
R/W
0 (disabling the mode),1 (digital operator),
-
1625h
Torque bias value
P037
R/W
-200 to +200
1 [%]
1626h
Torque bias polarity selection
P038
R/W
0 (as indicated by the sign), 1 (depending on the
operation direction), 05(Option)
-
1627h
Speed limit for torque-controlled
operation (forward rotation)
P039 (high)
R/W
0 to 12000
0.01 [Hz]
1628h
P039 (low)
R/W
1629h
Speed limit for torque-controlled
operation (reverse rotation)
P040 (high)
R/W
0 to 12000
0.01 [Hz]
162Ah
P040 (low)
R/W
162Bh
Speed / torque control switching
time
P041
R/W
0 to 1000
-
162Ch to
162Dh
(Reserved)
-
-
-
-
162Eh
Communication watchdog timer
P044
R/W
0 to 9999
0.01 [s]
162Fh
Inverter action on communication
error
P045
R/W
0 (tripping), 1 (tripping after decelerating and stopping
the motor), 2 (ignoring errors),
3 (stopping the motor after free-running),
4 (decelerating and stopping the motor)
-
1630h
DeviceNet polled I/O: Output
instance number
P046
R/W
0-20
-
1631h
(Reserved)
-
-
-
-
1632h
Inverter action on communication
idle mode
P048
R/W
0 (tripping), 1 (tripping after decelerating and stopping
the motor), 2 (ignoring errors),
3 (stopping the motor after free-running),
4 (decelerating and stopping the motor)
-
*2
: Available from version 3.0
Содержание WJ200-001L
Страница 2: ......
Страница 3: ......
Страница 49: ......
Страница 63: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 299: ......
Страница 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Страница 305: ......
Страница 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 387: ......
Страница 509: ......
Страница 552: ...Ver 3 43 External register number 1218h A021 HIGH 1219h A021 Low Internal register number 120Fh A013 Access Denied ...
Страница 665: ......
Страница 673: ......
Страница 674: ...Index 1 Index Index page A B C 2 D E F G H 3 I J K L M 4 N O P 5 Q R S 6 T U V W X Y Z 7 Index ...