Ver.3
−
−
−
−
124
““““A
A
A
A”””” Function
Function
Function
Function
A
A
A
A
B
B
B
B
D
D
D
Defaults
efaults
efaults
efaults
Func.
Func.
Func.
Func.
Code
Code
Code
Code
N
N
N
Name
ame
ame
ame
D
D
D
Description
escription
escription
escription
Initial data
Initial data
Initial data
Initial data
Units
Units
Units
Units
A
A
A
A2
2
2
26
6
6
61
1
1
1
Frequency upper limit,
2nd motor
Sets a limit on output frequency
less than the maximum frequency
(A
A
A
A2
2
2
20
0
0
04
4
4
4).
Range is from frequency lower
limit (A
A
A
A2
2
2
26
6
6
62
2
2
2) to maximum
frequency (A
A
A
A2
2
2
20
0
0
04
4
4
4).
0.0 setting is disabled
>0.0 setting is enabled
0.00
Hz
A
A
A
A0
0
0
06
6
6
62
2
2
2
Frequency lower limit
Sets a limit on output frequency
greater than zero.
Range is start frequency (b
b
b
b0
0
0
08
8
8
82
2
2
2) to
frequency upper limit (A
A
A
A0
0
0
06
6
6
61
1
1
1)
0.0 setting is disabled
>0.0 setting is enabled
0.00
Hz
A
A
A
A2
2
2
26
6
6
62
2
2
2
Frequency lower limit,
2nd motor
Sets a limit on output frequency
greater than zero.
Range is start frequency (b
b
b
b0
0
0
08
8
8
82
2
2
2) to
frequency upper limit (A
A
A
A2
2
2
26
6
6
61
1
1
1)
0.0 setting is disabled
>0.0 setting is enabled
0.00
Hz
A
A
A
A0
0
0
06
6
6
63
3
3
3
A
A
A
A0
0
0
06
6
6
65
5
5
5
A
A
A
A0
0
0
067
67
67
67
Jump freq. (center) 1 to 3
Up to 3 output frequencies can be
defined for the output to jump past
to avoid motor resonances (center
frequency)
Range is 0.00 to 400.0(580.0)
*1
Hz
0.00
0.00
0.00
Hz
A
A
A
A0
0
0
06
6
6
64
4
4
4
A
A
A
A0
0
0
066
66
66
66
A
A
A
A0
0
0
068
68
68
68
Jump freq. width
(hysteresis) 1 to 3
Defines the distance from the
center frequency at which the
jump around occurs
Range is 0.00 to 10.0 Hz
0.50
0.50
0.50
Hz
A
A
A
A0
0
0
069
69
69
69
Acceleration hold frequency Sets the frequency to hold
acceleration, range is 0.0 to
400.0(580.0)
*1
Hz
0.00
Hz
A
A
A
A0
0
0
07
7
7
70
0
0
0
Acceleration hold time
Sets the duration of acceleration
hold, range is 0.0 to 60.0 seconds
0.0
s
A
A
A
A0
0
0
07
7
7
71
1
1
1
PID enable
Enables PID function,
three option codes:
00
00
00
00
…
PID Disable
0
0
0
01
1
1
1
…
PID Enable
0
0
0
02
2
2
2
…
PID Enable with reverse
output
00
−
A
A
A
A0
0
0
07
7
7
72
2
2
2
PID proportional gain
Proportional gain has a range of
0.00 to 25.00
1.00
−
A
A
A
A0
0
0
07
7
7
73
3
3
3
PID integral time constant
Integral time constant has a range
of 0.0 to 3600 seconds
1.0
s
A
A
A
A0
0
0
07
7
7
74
4
4
4
PID derivative time
constant
Derivative time constant has a
range of 0.00 to 100.0seconds
seconds
0.00
s
A
A
A
A0
0
0
07
7
7
75
5
5
5
PV scale conversion
Process Variable (PV), scale factor
(multiplier), range of 0.01 to 99.99
1.00
−
A
A
A
A0
0
0
076
76
76
76
PV source
Selects source of Process Variable
(PV), option codes:
00
00
00
00
…
[OI] terminal (current in)
0
0
0
01
1
1
1
…
[O] terminal (voltage in)
0
0
0
02
2
2
2
…
Modbus network
0
0
0
03
3
3
3
…
Pulse train input
1
1
1
10
0
0
0
…
Calculate function output
00
−
A
A
A
A0
0
0
077
77
77
77
Reverse PID action
Two option codes:
00
00
00
00
…
PID input = SP-PV
0
0
0
01
1
1
1
…
PID input = -(SP-PV)
00
−
A
A
A
A0
0
0
078
78
78
78
PID output limit
Sets the limit of PID output as
percent of full scale,
range is 0.0 to 100.0%
0.0
%
Содержание WJ200-001L
Страница 2: ......
Страница 3: ......
Страница 49: ......
Страница 63: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 299: ......
Страница 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Страница 305: ......
Страница 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 387: ......
Страница 509: ......
Страница 552: ...Ver 3 43 External register number 1218h A021 HIGH 1219h A021 Low Internal register number 120Fh A013 Access Denied ...
Страница 665: ......
Страница 673: ......
Страница 674: ...Index 1 Index Index page A B C 2 D E F G H 3 I J K L M 4 N O P 5 Q R S 6 T U V W X Y Z 7 Index ...