14.1.4 Motor constants selection
•
When PM dive, adjust the motor constant settings to the motor to be driven by the inverter.
•
You can select the motor constants from the following three types:
(1)
Motor constants of Hitachi standard motor
⇒
When 00 is set on PM motor code setting (H102), motor constants use (H106~H110). Initial values
of (H106~H110) are set on motor constants of Hitachi standard motor.
(2)
Motor constants tuned by offline auto-tuning
⇒
When 01 is set on PM motor code setting (H102) after the offline auto-tuning allows, motor
constants use automatically measure values (H111~H113) and Hitachi standard motor values
(H109~H110).
(3)
Arbitrarily set motor constants
⇒
In above-mentioned both (1) and (2) cases, motor constants can be changed to the given value.
Please change the value of (H106~H113) in the value of (H102).
Item
Function
code
Data or range of data
Description
Base frequency (
*
1)
A003
30.0~Maximum frequency
[Hz]
The base frequency of
motor is set.
Maximum frequency (
*
1)
A004
Base frequency~400.0 [Hz]
The max frequency of
motor is set.
PM motor code setting
H102
00
Hitachi standard
(Use 106~H110 at motor
constants)
01
Auto-Tuning
(Use 106~H110 at motor
constants)
PM motor capacity (
*
2)
H103
0.1~18.5 [kW]
The capacity of motor is
set.
PM motor pole setting
H104
2/4/6/8/
‥
/48 [pole]
The pole of motor is set.
PM Rated Current
H105
(0.00~1.00)
×
Rated
current of the inverter [A]
The rated current of motor
is set.
Motor constants of Hitachi standard motor
Motor constants setting
when auto-tuning don't
use. The initial values are
motor constants of Hitachi
standard motor.
PM const R(Resistance)
H106
0.001~65.535 [Ω]
PM const Ld(d-axis inductance)
H107
0.01~655.35 [mH]
PM const Lq(q-axis inductance)
H108
0.01~655.35 [mH]
PM const Ke(Induction voltage
constant) (
*
3)
H109
0.0001~6.5535 [V/(rad/s)]
PM const J(Moment of inertia) (
*
4) H110
0.001~9999.000 [kgm
2
]
Motor constants tuned by offline auto-tuning
Automatically measured
motor constants when the
offline auto-tuning is
executed, and they are set.
After auto-tuning, you can
be changed to the given
value.
PM const R (Resistance)
H111
0.001~65.535 [Ω]
PM const Ld(d-axis inductance)
H112
0.01~655.35 [mH]
PM const Lq(q-axis inductance)
H113
0.01~655.35 [mH]
*
1 The base frequency (the maximum frequency) calculates to the following by the rated revolution (the
maximum revolution) of the motor and motor pole.
120
pole
]
)[min
revolution
(Maxmum
revolution
Rated
[Hz]
frequency)
(Maximum
frequency
Base
1
*
2 Please pay attention that settings of H104 to H110, A003 and A004 will be changed automatically, when PM
Содержание WJ200-001L
Страница 2: ......
Страница 3: ......
Страница 49: ......
Страница 63: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 299: ......
Страница 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Страница 305: ......
Страница 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 387: ......
Страница 509: ......
Страница 552: ...Ver 3 43 External register number 1218h A021 HIGH 1219h A021 Low Internal register number 120Fh A013 Access Denied ...
Страница 665: ......
Страница 673: ......
Страница 674: ...Index 1 Index Index page A B C 2 D E F G H 3 I J K L M 4 N O P 5 Q R S 6 T U V W X Y Z 7 Index ...