Ver.2
5
■
Way to PM mode switching
Note 1: For prevent from initializing by mistake, (b084) and (b180) restore 00 after initialize or Re-power supply.
Every time, please set it every time if you initialize.
Note 2: Even if initialize, the initial data select (b085), the input span calibration (C081, C082), and the
thermistor input (PTC) span calibration (C085) don't initialize.
Note 3: There is not any way to restore the previous parameter setting after initialize.
Japan
Europe
rotation
The content of initialization and the
operation mode after initialize blink
alternately while initializing.
PM mode
Content
Operation
mode
Blink alternately
Step 1:03 is selected by
b171, and push [SET] key.
SET
Step 2:01 is selected by
b180, and push [SET] key.
SET
Step 3:When the
initialization display
ends, it is initialization
completion.
Initialization
Complete
Содержание WJ200-001L
Страница 2: ......
Страница 3: ......
Страница 49: ......
Страница 63: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 299: ......
Страница 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Страница 305: ......
Страница 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 387: ......
Страница 509: ......
Страница 552: ...Ver 3 43 External register number 1218h A021 HIGH 1219h A021 Low Internal register number 120Fh A013 Access Denied ...
Страница 665: ......
Страница 673: ......
Страница 674: ...Index 1 Index Index page A B C 2 D E F G H 3 I J K L M 4 N O P 5 Q R S 6 T U V W X Y Z 7 Index ...