61
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
A
B
Initial data
Units
BRD activation level
(As DC Voltage)
If DC Voltage > b096,
the register consume. regeneration
power.
Range is:
330 to 380V (200V class)
660 to 760V (400V class)
360/
720
V
BRD register
Set the value of the register connected to
the inverter.By this setting, b090’s upper
limit as the inverter hardware is
calcurated automatically.So, you can
focus the usage ratio as the connected
register.
Range is minimum connectable register
Rbmin to 600.0[Ω]
Min.
Resistance
Ω
Free V/F setting, freq.1
Set range, 0 ~ value of
0.
Hz
Free V/F setting, voltage.1
Set range, 0 ~ 800V
0.0
V
Free V/F setting, freq.2
Set range, value of
~
0.
Hz
Free V/F setting, voltage.2
Set range, 0 ~ 800V
0.0
V
Free V/F setting, freq.3
Set range, value of
~
0.
Hz
Free V/F setting, voltage.3
Set range, 0 ~ 800V
0.0
V
Free V/F setting, freq.4
Set range, value of
~
0.
Hz
Free V/F setting, voltage.4
Set range, 0 ~ 800V
0.0
V
Free V/F setting, freq.5
Set range, value of
~
0.
Hz
Free V/F setting, voltage.5
Set range, 0 ~ 800V
0.0
V
Free V/F setting, freq.6
Set range, value of
~
0.
Hz
Free V/F setting, voltage.6
Set range, 0 ~ 800V
0.0
V
Free V/F setting, freq.7
Set range,
~ 400
0.
Hz
Free V/F setting, voltage.7
Set range, 0 ~ 800V
0.0
V
Brake control enable
Two option codes:
Disable
Enable
00
-
Brake Wait Time for Release Set range: 0.00 to 5.00 seconds.
0.00
s
Brake Wait Time for
Acceleration
Set range: 0.00 to 5.00 seconds.
0.00
s
Brake Wait Time for
Stopping
Set range: 0.00 to 5.00 s seconds.
0.00
s
Brake Wait Time for
Confirmation
Set range: 0.00 to 5.00 seconds.
0.00
s
Brake release freq.
Set range: 0 to 400Hz
0.00
Hz
Brake release current
Set range: 0~200% of inverter rated
current
(rated
current)
A
Braking freq. setting
Set range: 0 to 400Hz
0.00
Hz
Deceleration overvoltage
suppression enable
Disabled
Enabled
Enabled with accel.
00
Decel. overvolt. suppress
level
DC bus voltage of suppression. Range is:
200V class
330 to 395
400V class
660 to 790
380
/760
V
Содержание WJ200-001L
Страница 2: ......
Страница 3: ......
Страница 49: ......
Страница 63: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 299: ......
Страница 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Страница 305: ......
Страница 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 387: ......
Страница 509: ......
Страница 552: ...Ver 3 43 External register number 1218h A021 HIGH 1219h A021 Low Internal register number 120Fh A013 Access Denied ...
Страница 665: ......
Страница 673: ......
Страница 674: ...Index 1 Index Index page A B C 2 D E F G H 3 I J K L M 4 N O P 5 Q R S 6 T U V W X Y Z 7 Index ...