Ver.2
57
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
A
B
Initial data
Units
Level of electronic thermal,
2
nd
motor
rated inverter current.
current for
each
inverter
model *1
A
Electronic thermal
characteristic
Select from three curves, option codes:
Reduced torque
Constant torque
Free setting
01
Electronic thermal
characteristic, 2
nd
motor
01
Free setting electronic
thermal ~freq.1
Range is 0 to 400Hz
0.0
Hz
Free setting electronic
thermal ~current1
Range is 0 to inverter rated current Amps
0.00
A
Free setting electronic
thermal ~freq.2
Range is 0 to 400Hz
0.0
Hz
Free setting electronic
thermal ~current2
Range is 0 to inverter rated current Amps
0.00
A
Free setting electronic
thermal ~freq.3
Range is 0 to 400Hz
0.0
Hz
Free setting electronic
thermal ~current3
Range is 0 to inverter rated current Amps
0.00
A
Overload restriction
operation mode
Select the operation mode during
overload conditions, four options, option
codes:
Disabled
Enabled for acceleration and
constant speed
Enabled for constant speed only
Enabled for acceleration and
constant speed, increase speed at
regen.
01
Overload restriction
operation mode, 2
nd
motor
01
Overload restriction level
Sets the level of overload restriction,
between 20% and 200% of the rated
current of the inverter, setting resolution
is 1% of rated current
Rated
current
x 1.5
A
Overload restriction level,
2
nd
motor
Rated
current
x 1.5
A
Deceleration rate at overload
restriction
Sets the deceleration rate when inverter
detects overload, range is 0.1 to 3000.0,
resolution 0.1 seconds.
1.0
s
Deceleration rate at overload
restriction, 2
nd
motor
1.0
s
Overload restriction
operation mode 2
Select the operation mode during
overload conditions, four options, option
codes:
Disabled
Enabled for acceleration and
constant speed
Enabled for constant speed only
Enabled for acceleration and
constant speed, increase speed at
regen.
01
Overload restriction level 2
Sets the level of overload restriction,
between 20% and 200% of the rated
current of the inverter, setting resolution
is 1% of rated current
Rated
current
x 1.5
Deceleration rate 2 at
overload restriction
Sets the deceleration rate when inverter
detects overload, range is 0.1 to 3000.0,
resolution 0.1 seconds.
1.0
s
OC suppression selection *
Two option codes:
Disabled
Enabled
00
Содержание WJ200-001L
Страница 2: ......
Страница 3: ......
Страница 49: ......
Страница 63: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 299: ......
Страница 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Страница 305: ......
Страница 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 387: ......
Страница 509: ......
Страница 552: ...Ver 3 43 External register number 1218h A021 HIGH 1219h A021 Low Internal register number 120Fh A013 Access Denied ...
Страница 665: ......
Страница 673: ......
Страница 674: ...Index 1 Index Index page A B C 2 D E F G H 3 I J K L M 4 N O P 5 Q R S 6 T U V W X Y Z 7 Index ...