3
104
“H” Group: Motor Constants Functions
The “H” Group parameters configure the
inverter for the motor characteristics. You must
manually set
and
values to match the
motor. Parameter
is factory-set. If you
want to reset the parameters to the factory
default settings, use the procedure in “Restoring
Factory Default Settings” on in section 6.. Use
to select the torque control algorithm as
shown in the diagram.
Please refer to chapter 4 for detailed explanation of the auto-tuning.
“H” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
Units
Auto-tuning selection
Three option codes:
Disabled
Enabled with motor stop
Enabled with motor rotation
00
Motor constant selection
Two option codes:
Hitachi standard motor
Auto tuned data
00
Motor constant selection,
2
nd
motor
00
Motor capacity
Twelve selections:
0.1/0.2/0.4/0.75/1.5/2.2/3.7/
5.5/7.5/11/15/18.5
Specified by
the capacity
of each
inverter
model
kW
Motor capacity,
2
nd
motor
kW
Motor poles setting
Five selections:
2 / 4 / 6 / 8 / 10
4
poles
Motor poles setting,
2
nd
motor
4
poles
Motor speed response
constant
Set range is 1 to 1000
100.
Motor speed response
constant, 2
nd
motor
100.
Motor stabilization
constant
Motor constant (factory set),
range is 0 to 255
100.
Motor stabilization
constant, 2
nd
motor
100.
Motor constant R1
(Hitachi motor)
0.001~65.535 ohms
Specified by
the capacity
of each
inverter mode
Ohm
Motor constant R1,
2
nd
motor (Hitachi motor)
Ohm
Motor constant R2
(Hitachi motor)
0.001~65.535 ohms
Ohm
Motor constant R2,
2
nd
motor (Hitachi motor)
Ohm
V/F control
constant torque (V/F-VC)
Output
Inverter Torque Control Algorithms
V/F control,
variable (1.7) torque
V/F control,
Free V/f
Sensorless vector
Control (SLV)
Содержание WJ200-001L
Страница 2: ......
Страница 3: ......
Страница 49: ......
Страница 63: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 299: ......
Страница 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Страница 305: ......
Страница 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 387: ......
Страница 509: ......
Страница 552: ...Ver 3 43 External register number 1218h A021 HIGH 1219h A021 Low Internal register number 120Fh A013 Access Denied ...
Страница 665: ......
Страница 673: ......
Страница 674: ...Index 1 Index Index page A B C 2 D E F G H 3 I J K L M 4 N O P 5 Q R S 6 T U V W X Y Z 7 Index ...