3-49
SECTION 3 –
CAB
•
On the “Air Purge Settings” screen,
press EDIT (next to Full Boom Purge).
•
Enter desired value (amount of time that
the entire boom will purge), then press
OK.
•
Press OK.
Individual Section Purge
•
Press the Air Purge Button (located on
the Settings Page).
•
On the “Air Purge Settings” screen,
press EDIT (next to Individual Section
Purge).
•
Enter desired value (amount of time that
each individual section will purge), then
press OK.
•
Press OK.
NOTE: When purging individual sections,
the system will start with the leftmost
section that is not turned off (on the
section keypad) and continue to the
rightmost section that is not turned
off.
Example:
If Sections 1, 2, 8, and 9 are turned
off and all others are on, then
Sections 3-7 will be purged. The left
fence row nozzle will be purged
when Section 1 is purged (and full
boom), and the right fence row
nozzle will be purged when Section 9
is purged (and full boom), unless the
fence row nozzles are turned off
through the section keypad. The rear
nozzle will purge with Section 5 (and
full boom), unless the rear nozzle is
turned off through the section
keypad.
Air Recharge Time
•
Press the Air Purge Button (located on
the Settings Page).
•
On the “Air Purge Settings” screen,
press EDIT (next to Air Recharge Time).
•
Enter desired value (amount of time that
it takes to recharge the air tank), then
press OK.
•
Press OK.
Minimum Engine Speed
•
Press the Air Purge Button (located on
the Settings Page).
•
On the “Air Purge Settings” screen,
press EDIT (next to Minimum Engine
Speed).
•
Enter desired RPM, then press OK.
NOTE: Engine throttle must be above 1800
RPM. This will allow the air tank to
recharge faster.
•
Press OK.
To Activate the Air Purge System in
Automatic Mode
•
Ensure the Solution Pump Switch
(located on the side console) is in the
OFF position.
•
Ensure the solution tank, rinse, and agi-
tation valves are CLOSED.
NOTE: Press and hold the Agitation Valve
Switch (located on the side console)
in the DOWN position for
approximately 10 seconds to ensure
the agitation valve is closed.
•
Throttle engine to desired RPM (above
1800 RPM).
•
Ensure that no system faults are pres-
ent.
•
Press the Air Purge Button (located on
the Auxiliary Controls Page).
Air Purge Settings Screen
Содержание UpFront STS 16
Страница 3: ...Ladder Fuel Fill 10 21 Tall Crop Package Installation 10 24 Troubleshooting 10 37...
Страница 341: ......