SECTION 7 –
SPRAY SYSTEMS
7-61
2. Rotate the Inlet Selector Valve(s)
(located near the bottom right-hand side
of chemical tank(s)) to the to “FROM
CHEM TANK” position.
3. Rotate the Outlet Selector Valve(s)
(located on the front of injection
pump(s)) to the “TO TANK” position. This
will allow the chemical to divert back to
the tank rather than the booms during
the calibration process.
NOTE: Refer to the provided label for valve
handle orientation. See following
illustration.
4. When pump calibration is complete,
rotate the Outlet Selector Valve(s) to the
“TO BOOM” position to send chemical to
the Mixer Assembly.
Injection Pump(s)
(Located near the bottom
of chemical tank(s))
-Typical View
* 1-tank/1-pump configuration shown
Inlet Selector Valve(s)
(Located near the bottom
right-hand side of chemical tank(s))
-Typical View
* 1-tank/1-pump configuration shown
Outlet Selector Valve(s)
(Located on the front of injection pump(s))
-Typical View
* 1-tank/1-pump configuration shown