8-35
SECTION 8 –
DUAL PRODUCT SPRAY SYSTEMS
To Drain the Solution Tank
1. Loosen the metal flange clamp and
remove Drain Valve Plug (located on the
end of the Solution Tank Drain Valve
Assembly of the tank side you desire to
drain) and set aside.
2. Connect an operator-supplied hose to
the tank drain outlet (where Drain Valve
Plug was previously removed).
3. Turn the Solution Tank Drain Valve in
the OPEN (counter-clockwise) position
and allow solution to drain into an appro-
priate container for storage.
NOTE: Always ensure that storage
containers and clearly marked with
what type of chemical is being
stored.
4.
When finished draining the solution
tank
, turn the Solution Tank Drain Valve
in the CLOSED (clockwise) position.
5. Remove hose from the tank drain outlet.
6. Reinstall Drain Valve Plug and tighten
metal flange clamp.
7. Repeat Steps 1-6 to drain solution from
opposite side of tank.
APPLICATION - DUAL
PRODUCT
It is important to apply chemicals as
recommended by the manufacturer. In order
to do so, the spray system console must be
properly calibrated.
NOTE: Refer to the spray system console
manufacturer’s operation manual for
calibration instructions.
NOTICE
When draining large volumes from the
solution tank, it is recommended to
pump off with the solution pump through
the front quick coupler.
Solution Tank Drain Valve Assemblies (2)
(Located beneath the solution
tank on underside of machine)
-Typical View
* View looking towards rear of machine
• Tank 1
Drain Valve
Assembly
• Tank 2
Drain Valve
Assembly
Solution Tank Drain Valve Assembly
(Located beneath the solution
tank on underside of machine)
-Typical View
* Tank 1 drain valve assembly shown
• Drain
Valve
Plug
• Metal Flange
Clamp
• Solution
Tank Drain
Valve