C.1.2.3 Electrical Software Verification
Follow the instructions below to verify the correct electrical software is loaded.
1.
Place the G900X in Normal mode.
2.
Verify the correct electrical system by determining the corresponding gauge title and gauge range
listed below. Use Table C-5 for piston aircraft and Table C-6 for turboprop aircraft.
Table C-5. G900X Electrical Software Verification Table
Electrical System
Gauge
Title
Gauge
Range
Configured
Electrical
Software
(Check Up To
Three)
14 Volt
MAIN V
10 to 17
28 Volt
MAIN V
23 to 33
60 Amp Alternator
ALT A
0 to 70
70 Amp Alternator
ALT A
0 to 80
80 Amp Alternator
ALT A
0 to 90
100 Amp Alternator
ALT A
0 to 110
Standby Battery (Optional)
AUX A
-30 to 70
Standby Ammeter (Optional)
AUX A
0 to 70
Table C-6. G900X Turboprop Electrical Software Verification Table
Electrical System
Gauge
Title
Gauge
Range
Configured
Electrical
Software
28 Volt System, 300 Amp Generator,
100 Amp Alternator
VOLTS
0 to 33