15.2.3.6 Electrical_Piston
Selection Order
4
th
Required?
Yes, except for No-EIS installations.
Multiple Selections
Allowed?
Yes
Purpose
The “Electrical_Piston” configuration parameters set the
appropriate voltage and ammeter display ranges as well as an
optional auxiliary ammeter if installed.
The following selections are available for configuration of the selected G900X/G950 electrical piston
system:
Main and essential bus voltage (1 required):
•
14 Volt System
•
28 Volt System
Primary alternator capacity (1 required):
•
60 Amp Alternator
•
70 Amp Alternator
•
80 Amp Alternator
•
100 Amp Alternator
Auxiliary ammeter display (1 optional):
•
Standby Battery
•
Standby Alternator
1.
Activate the cursor and use the FMS knob to highlight “Electrical” in the AIRFRAME field.
2.
Press the ENT key.
3.
Using the FMS knob, select the appropriate electrical system (14 or 28 Volt System) in the FILE
field.
Figure 15-12. Example Electrical – System Upload Page
4.