Page 11-10
G900X/G950 Installation and Maintenance Manual – GWX 68
Revision D
190-00719-00
8.
Guidelines for terminating the newly cutoff Flat Braid(s) (item 6) with insulated ring terminals (9):
•
Each tapped hole on the Shield Block (2) may accommodate only two ring terminals (9).
•
It is preferred that only two Flat Braids (6) be terminated per ring terminal. Two Flat Braids per
ring terminal will necessitate the use of a Ring terminal, #8, insulated, 14-16 AWG
(MS25036-153).
•
If only a single Flat Braid is left or if only a single Flat Braid is need for this connector, a Ring
terminal, #8, insulated, 18-22 AWG (MS25036-149) can accommodate this single Flat Braid.
•
If more braids exist for this connector than two per ring terminal, it is permissible to terminate
three braids per ring terminal. This will necessitate the use of a Ring terminal, #8, insulated,
10-12 AWG (MS25036-156).
•
In rare situations where more braids need to be terminated for this connector than three per ring
terminal it is allowable to daisy chain a maximum of two shields together before coming to the
ring terminal. (See Figure 11-3).
Figure 11-3. Daisy Chain Method for Shield Termination