13.9.1 ID Program Pins (Strapping)
ID Program Pins provide a ground reference used by the hardware as a means of configuration for system
identification. The following instructions will illustrate how this ground strapping should be
accomplished with the Shield Blocks:
A1.
Cut a 4 inch length of 22 AWG insulated wire.
WARNING
Flat Braid is not permitted for this purpose. Use only insulated wire to avoid inadvertent
ground issues that could occur from exposed conductors.
A2.
Strip back 0.125 inches of insulation and crimp a pin (item 8) to the 4” length of 22 AWG
insulated wire.
A3.
Insert newly crimped pins and wires into the appropriate connector housing location as
specified by the installation wiring diagrams.
A4.
At the end opposite the pin on the 22 AWG insulated wire strip back 0.2 inches of insulation.
A5.
Terminate this end via the ring terminals with the other Flat Braid per Steps 8 and 11 pertaining
to shield termination. If this ground strap is only wire to terminate, attach a Ring terminal, #8,
insulated, 18-22 AWG (MS25036-149).