13.3.1 Shield Termination Technique - Method A.2 (Daisy Chain)
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together before coming to the ring terminal (see
Figure 13-4). All other restrictions and instructions for the shield termination technique set forth for
Method A.1 are still applicable.
NOTE
The maximum length of the combined braids should be approximately
4 inches.
0.75 INCHES MIN.
0.17 INCHES
0.35 INCHES MAX.
WINDOW MAX.
WINDOW MIN.
FLOAT MIN. TO FLOAT MAX.
7
6
5
6
5
FOR REF. ONLY
SEE FIGURE 13-3
Figure 13-4. Method A.2 (Daisy Chain) for Shield Termination