G900X/G950 Installation and Maintenance Manual – Non LRU Specific Installation Information
Page 13-13
190-00719-00
Revision D
13.6.1 Daisy Chain between Methods A and B
In rare situations where more braids need to be terminated for a connector than three per ring terminal and
a mixture of Methods A and B have been used, it is allowable to daisy chain a maximum of two shields
together from a Method A termination to a Method B (see Figure 13-7). All other restrictions and
instructions for the shield termination technique set forth for Method A and B are still applicable.
NOTE
The maximum length of the combined braids should be approximately
4 inches.
0.75 INCHES MIN.
0.17 INCHES
0.35 INCHES MAX.
WINDOW MAX.
FLOAT MIN. TO FLOAT MAX.
7
6
5
0.35 INCHES MAX.
6
5
FOR REF. ONLY
SEE FIGURE 13-3
Figure 13-7. Daisy Chain between Methods A and B