Topclean S
4 Wiring and pneumatic connection of Topclean S
Hauser
37
4.3.5
CPA473 / 474 assemblies
with inductive limit switches
The assembly is delivered completely hosed up. All
you have to do is connect compressed air for
pneumatic operation of the ball valve to the
pneumatic terminal block.
1.
Screw the multihose onto the bayonet lock,
ensuring it is strain relieved and free of kinks.
2.
Fold hoses no. 5 and 6 back into the multihose.
3.
Connect
hose no. 2
for position "Measure"
from the multihose to input "2" of the
assembly’s pneumatic connection block.
4.
Connect
hose no. 3
for position "Service" from
the multihose to input "3" of the assembly’s
pneumatic connection block.
5.
Connect the motive water line (D) via a pipe
disconnector (E) to the G3/8 connection of
CYR10.
6.
Connect the line for conveyance of cleaning
agent (C) to the G¼ connection of CYR10.
7.
Connect the line from CYR10 to the assembly
as follows:
– If you are not using the CPR40 rinse block
(A), connect the line to the rinse water inlet
of the assembly.
– If you are a using the CPR40 rinse block (A),
connect the line to the "T" connection of
CPR40.
8.
If you are using an external valve, connect the
line for steam, additional cleaning agents or
sealing water (B) to the other connection of
CPR40.
9.
If you are using a pneumatic outlet safety
seal (G):
– Connect the connection 2 (= outlet) of the
limit position switch on the ball valve drive
to input "6" of the assembly’s pneumatic
connection block.
– Connect output "6" of the assembly’s pneu-
matic connection block to the compressed
hose connection of the outlet safety seal.
!
Note!
The maximum hose length is 10 m / 32.81 ft:
• Maximum discharge height: 5 m / 16.41 ft
• Max. horizontal discharge width: 10 m / 32.81 ft
• Pressure resistance of internal components:
up to 7 bar / 101.5 psi
• Maximum suction height of buffer/cleaning
agent: 2 m / 6.56 ft
C07-CPC30xxx-12-04-00-xx-019.eps
ƒig. 33:
Connection of CPA473 / 474 assemblies with inductive limit position switches
A
CPR40 rinse block, required for Topclean versions with external valve control for con-
veyance of hot, aggressive or pressurised media
B
Pressurised steam, water, cleaning agent
C
Cleaner
D
Motive water 2 ... 7 bar / 29 ... 101.5 psi
E
Pipe disconnector (customer supplied)
F
CYR10
G
Outlet safety seal (optional)
Содержание Topclean S CPC30
Страница 154: ...10 Technical data Topclean S 154 Endress Hauser...
Страница 156: ...11 Appendix Topclean S 156 Endress Hauser C07 CPC30xxx 19 06 08 en 006 eps...
Страница 157: ...Topclean S 11 Appendix Endress Hauser 157 C07 CPC30xxx 19 06 08 en 007 eps...
Страница 158: ...11 Appendix Topclean S 158 Endress Hauser C07 CPC30xxx 19 06 08 en 008 eps...
Страница 159: ...Topclean S 11 Appendix Endress Hauser 159...
Страница 160: ...11 Appendix Topclean S 160 Endress Hauser C07 CPC30xxx 19 06 08 en 002 eps...
Страница 161: ...Topclean S 11 Appendix Endress Hauser 161 C07 CPC30xxx 19 06 08 en 003 eps...
Страница 162: ...11 Appendix Topclean S 162 Endress Hauser C07 CPC30xxx 19 06 08 en 014 eps...
Страница 163: ...Topclean S 11 Appendix Endress Hauser 163 C07 CPC30xxx 19 06 08 en 015 eps...
Страница 164: ...11 Appendix Topclean S 164 Endress Hauser C07 CPC30xxx 19 06 08 en 011 eps...
Страница 165: ...Topclean S 11 Appendix Endress Hauser 165 C07 CPC300xx 19 06 08 en 010 eps...
Страница 166: ...11 Appendix Topclean S 166 Endress Hauser C07 CPC30xxx 19 06 08 en 012 eps...
Страница 167: ...Topclean S 11 Appendix Endress Hauser 167 C07 CPC30xxx 19 06 08 en 013 eps...
Страница 176: ...Index Topclean S 176 Endress Hauser...
Страница 178: ...www endress com worldwide BA236C 07 en 11 04 51504339 Printed in Germany FM SGML 6 0 DT...