First start up
In the First start up menu, configure the most important transmitter functions. The First start up ist
started automatically when starting the instrument for the first time. You can open the First start up
at any time from the menu structure.
To enter the menu, proceed as follows:
⇒
⇒
⇒
Display
CHOICE
(default = bold)
INFO
E
D
Select language
Depending on ordered language version:
Language version variants:
-A: English / German
-B: English / French
-C: English / Italian
-D: English / Spanish
-E: English / Dutch
-F: English / Japanese
Contrast setting as necessary
You can increase and reduce the contrast with the +/- keys.
Mo
01
04
01
12:00
Date and time entry
Enter the complete date and time here.
pH
Redox mV
Redox %
Operating mode selection
!
Note!
• If the operating mode changes, all the user settings are automatically reset!
• For digital sensors with Memosens technology, only the pH operating mode is
available.
• Here it is sensible to use the DAT module to save your settings.
Glass el. 7.0
Glass el.4.6
Antimony
ISFET
Select electrode type
(only pH)
!
Note!
• In the event of a change from glass or antimony electrode to ISFET, the temperature
sensor is reset to Pt 1000 as a default. Conversely, Pt 100 is selected.
• The Topclean S version glass / ISFET (CPC30-xx2xxxxxxx) is factory set for
measurement with glass electrodes.
• For digital sensors with Memosens technology, only the electrode type Glass el. 7.0
is available.
PARAM
pH
7.00
Param
Operating level
Read only
Operator
Specialist
Edit
Next E
Hold
pH
7.00
Param
Edit
Next
Operating level
E
Hold
000
0...9997
Spec. access code
0
pH
7.00
Param
Settings
Set up 1
Set up 2
Manual operation
First start up
Edit
Next E
Hold
pH
7.00
Param
English
Deutsch
Edit
D
GB
Hold
Language
Next
E
Hold
pH
7.00
Param
Edit
+-
Contrast
Next E
Hold
30
04
01
00
12
pH
7.00
Param
Date+time
Weekday
Day
Month
Year
Next
Time
Mo
Select
E
pH
7. 00
Hold
Param
pH
Edit
[¯ ]
[E]
Sensor input
Redox/ORP mV
Redox/ORP %
Next
Hold
pH
7.00
Param
Edit
E
Antimon
IsFET
pH electr.typeK1
Next
Glass El. 7.0
Glass El. 4.6
Содержание Topclean S CPC30
Страница 154: ...10 Technical data Topclean S 154 Endress Hauser...
Страница 156: ...11 Appendix Topclean S 156 Endress Hauser C07 CPC30xxx 19 06 08 en 006 eps...
Страница 157: ...Topclean S 11 Appendix Endress Hauser 157 C07 CPC30xxx 19 06 08 en 007 eps...
Страница 158: ...11 Appendix Topclean S 158 Endress Hauser C07 CPC30xxx 19 06 08 en 008 eps...
Страница 159: ...Topclean S 11 Appendix Endress Hauser 159...
Страница 160: ...11 Appendix Topclean S 160 Endress Hauser C07 CPC30xxx 19 06 08 en 002 eps...
Страница 161: ...Topclean S 11 Appendix Endress Hauser 161 C07 CPC30xxx 19 06 08 en 003 eps...
Страница 162: ...11 Appendix Topclean S 162 Endress Hauser C07 CPC30xxx 19 06 08 en 014 eps...
Страница 163: ...Topclean S 11 Appendix Endress Hauser 163 C07 CPC30xxx 19 06 08 en 015 eps...
Страница 164: ...11 Appendix Topclean S 164 Endress Hauser C07 CPC30xxx 19 06 08 en 011 eps...
Страница 165: ...Topclean S 11 Appendix Endress Hauser 165 C07 CPC300xx 19 06 08 en 010 eps...
Страница 166: ...11 Appendix Topclean S 166 Endress Hauser C07 CPC30xxx 19 06 08 en 012 eps...
Страница 167: ...Topclean S 11 Appendix Endress Hauser 167 C07 CPC30xxx 19 06 08 en 013 eps...
Страница 176: ...Index Topclean S 176 Endress Hauser...
Страница 178: ...www endress com worldwide BA236C 07 en 11 04 51504339 Printed in Germany FM SGML 6 0 DT...