NS 5.14 Firmware
3
–
26
4900002262 rev. B 3-23-21
•
ppmv ConvFactor 00
: Sets a custom conversion factor when the
parameter Concentration Unit = 0 (ppmv) and this value is greater
than 0.0. The default conversion factor is used when it is equal to 0.0.
•
ppmw ConvFactor 04
: Sets a custom conversion factor when the
parameter Concentration Unit = 4 (ppmw) and this value is greater
than 0.0. The default conversion factor is used when it is equal to 0.0.
•
Pressure
: Current measured (live) wet pressure reading of the gas
sample in selected engineering units.
•
Pressure Unit
: Designates the display units for the measured
absolute pressure in the cell.
•
Propane
: Sets the mole fraction of propane in the dry gas mixture
used when calculating the dew point temperature per ISO
18453:2006. The default value (0.01763) corresponds to the natural
gas mixture NG3.
•
RATA
: Enables or disables user definable values that allow
adjustment (without affecting the factory calibration) of the analyzer
reading in the field. Refer to
“Adjusting Analyzer Reading to
•
RATA Multiplier
: User definable value that enables adjustment
(without affecting the factory calibration) of the analyzer response
(or slope) in the field. Refer to
“Adjusting Analyzer Reading to
•
RATA Multiplier Proposed
: The latest proposed RATA multiplier
value calculated based on the last validation run.
•
RATA Offset
: User definable value that enables adjustment (without
affecting the factory calibration) of the analyzer offset in the field.
Refer to
“Adjusting Analyzer Reading to Match Specific
•
RATA Offset Proposed
: The latest proposed RATA offset value
calculated based on the last validation run.
•
Set Time - Year
: Sets the current year for the real time clock.
•
Set Time - Month
: Sets the current month for the real time clock.
•
Set Time - Day
: Sets the current day for the real time clock.
•
Set Time - Hour
: Sets the current hour for the real time clock.
•
Set Time - Minute
: Sets the current minute for the real time clock.
•
Start Validation
: Initiates a validation cycle.
•
Status Flags
: Bitwise value identifying the occurrence of various
events in the analyzer, as listed in Table 3–3 on page 3–27.
Содержание SpectraSensors SS2000e
Страница 2: ......
Страница 4: ......
Страница 8: ...NS 5 14 Firmware iv 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 10: ...NS 5 14 Firmware vi 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 12: ...NS 5 14 Firmware viii 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 100: ...NS 5 14 Firmware 4 10 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 106: ...NS 5 14 Firmware A 6 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 112: ...NS 5 14 Firmware Index 6 4900002262 rev A 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 113: ......
Страница 114: ...www spectrasensors com contact 4900002262 Rev B...