OMMUNICATIONS
Receiving Serial Data (Customer Port Output)
When the
Modbus Mode
parameter is set to
0
, the analyzer is configured to
transfer a string of data from the analyzer to a serial device via the customer
port output. The receiving device is typically a computer terminal running
HyperTerminal, which is a program included with Microsoft
®
Windows
®
95, 98
and XP that enables serial communication and the viewing, capturing and
storage of serial port data and messages.
To launch HyperTerminal
1.
On your Windows desktop, click
Start
followed by
Run
(usually
located in the lower right window of the Start Menu).
2.
Type
Hypertrm.exe
and hit
Return
to launch HyperTerminal.
3.
Once HyperTerminal is activated, the
Connection Description
window appears, as shown in Figure 3–1 on page 3–2. Type in a
Filename
(where the terminal session settings will be stored for
future recall) and click on any icon. Click
OK
.
4.
The
Connect To
window appears prompting for a connection, as
shown in Figure 3–2 on page 3–2. Click the
Menu Arrow
under
Connect Using
to view the choices.
5.
Click on the appropriate port to which your analyzer is connected
(COM1, COM2, COM3, etc.). Click
OK
.
6.
Once the port is chosen, the
COM Properties
window appears.
Make sure the COM properties for the port selected reflect those
shown in Figure 3–3 on page 3–3 (19200 baud or as set in
Mode 2
,
8 data bits, 1 stop bit, no parity, and no flow control).
7.
Click
OK
to establish the connection.
Mode 1 data string
Once connected, the data will start streaming through the HyperTerminal
Window as shown in Figure 3–4 on page 3–3. The data string is tab delimited
(each row starting with a tab) forming 23 columns in the following order:
•
Date
: Current date (in MM:DD:YY)
•
Time
: Current time (in HH:MM:SS)
For quicker access to HyperTerminal, save a HyperTerminal
shortcut to the desktop.
Содержание SpectraSensors SS2000e
Страница 2: ......
Страница 4: ......
Страница 8: ...NS 5 14 Firmware iv 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 10: ...NS 5 14 Firmware vi 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 12: ...NS 5 14 Firmware viii 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 100: ...NS 5 14 Firmware 4 10 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 106: ...NS 5 14 Firmware A 6 4900002262 rev B 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 112: ...NS 5 14 Firmware Index 6 4900002262 rev A 3 23 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 113: ......
Страница 114: ...www spectrasensors com contact 4900002262 Rev B...