The OneCommand Utility User Manual
Page 215
Cannot see other adapters or hosts.
Although the OneCommand Manager
application is installed, only local adapters
are visible. The other adapters and hosts in
the SAN cannot be seen.
All the adapters in the SAN will be visible if:
• The other servers have a connection to your zone of the
SAN. Check fabric zoning.
• The elxhbamgr processes are running on remote hosts (enter
ps -ef | grep elxhbamgr).
• All other adapters are running the OneCommand Manager
application and the appropriate driver.
• The other adapters are Emulex adapters.
Note: The OneCommand Manager application services must be
running on all remote hosts that are to be discovered and
managed.
Cannot see new LUNs.
Try the following:
1. Refresh the screen.
2. Exit the OneCommand Manager application and restart the
OneCommand Manager application. If new LUNs are visible,
you are finished.
If that doesn't work, try the following:
1. Exit the OneCommand Manager application.
2. Navigate to /usr/sbin/hbanyware.
3. Run ./stop_ocmanager to stop both the elxhbamgr and
elxdiscovery processes.
4. Run ./start_ocmanager and ./start_elxdiscovery to restart
both processes.
5. Start the OneCommand Manager application.
Unwanted remote servers appear in the
OneCommand Manager application.
To remove out-of-band (TCP/IP) managed systems:
1. From the main menu, select Discovery-->TCP/IP--
>Remove Host(s)...
2. Select all hosts that you would like to stop discovering.
3. Select Remove.
4. Click Done to exit.
To remove in-band (Fibre Channel) managed systems:
1. Log into the remote systems that you would like to stop
discovering.
2. Stop the elxhbamgr processes:
• Windows: Stop the "Emulex HBA Management" service.
• Linux: Run the /usr/sbin/hbanyware/stop_ocmanager script.
• Solaris: Run the /opt/HBAnyware/stop_ocmanager script.
Table 6: Emulex Driver for Linux and OneCommand Manager Application Situations (Continued)
Situation
Resolution