The OneCommand Utility User Manual
Page 97
2.
Select the FIP tab.
3.
Set the parameters you want and click Apply Changes.
Figure 51: FIP tab for FCoE adapters
FIP Dialog Box Field Descriptions
CEE Settings Area
•
Primary Fabric Name - Indicates the FC Fabric's WWN to which to connect. If the Primary Fabric
Name is wild, i.e. all 0xFFs, then connection to any fabric name is allowed.
•
Primary Switch Name - Indicates the FC Switch's WWN to which to connect. If the Primary
Switch Name is wild, i.e. all 0xFFs, then connection to any switch name is allowed.
•
VLAN ID - Determines the VLAN where the adapter FCoE services are available. It can have a
value from 0-4095 and supports wild card values if “Any” is checked.
•
Any VLAN ID is valid check box - When checked, the VLAN ID field of the FCoE forwarder can
be any valid value.
Note: CEE settings are only applicable when the DCBX Mode in the CEE tab is set to CEE.
Note: In the illustration, the "CEE (FIP) Settings" group box also has "Active" its title. This
means that CEE (FIP) is the current DCBX mode (DCBX mode is set from the CEE
tab). If CIN (Non-FIP) were the current DCBX mode, "Active" would be in the "CIN
(Non-FIP) Settings" group box title.