8 Station variants
8.6 CAN objects for station variants
366
Gateway XN-312-GW-CAN
06/16 MN050003-DE www.eaton.eu
8.6 CAN objects for station variants
8.6.1 Activation StationVariants Mode (Object 0x4005)
Object 0x4005 must be set to 0x01 during the gateway's initialization phase.
Otherwise, the lists for the full configuration and the station variant will be
deleted from the gateway and the gateway will be restarted.
"Activation StationVariants Mode"=TRUE tells the gateway that it must not
start transferring data immediately after switching to the "OPERATIONAL"
CANopen status, and that it must instead wait for an enable signal from the
enable process.
The object's data is automatically entered into the transmit PDOs (default
mapping).
Design of the data byte:
8.6.2 Checksum (internal) (Object 0x4006)
Object 0x4006 is addressed exclusively from the IEC library. The returned
checksum provides clear feedback indicating which reduced assembly is
active on the gateway.
Feature
Description / Value
EDS
Type name
Activation StationVariants Mode
[4005]
ParameterName=Activation StationVariants
Mode
ObjectType=0x7
DataType=0x0005
AccessType=rw
PDOMapping=0
DefaultValue=0
Description
Activation StationVariants Mode
Object Code
ARRAY
Mapping
SDO
Default
Data type
UNSIGNED8
Sub index
01 … FE
hex
Access
rw
Default value
0000
hex
Data bit
Description
Notes
0
0 = Start gateway with target configura-
tion
1 = Switch gateway to "station variants"
operating status
1-7
reserved
Содержание XN-312-GW-CAN
Страница 1: ...Manual CANopen Gateway XN 312 GW CAN 06 16 MN050003 EN ...
Страница 4: ...II ...
Страница 14: ...10 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton com ...
Страница 374: ...9 What Happens If 370 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton eu ...
Страница 388: ...384 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton eu ...