7 Product-specific CAN objects XN300 slice modules
7.25 XN-322-1CNT-8DIO
Gateway XN-312-GW-CAN 06/16 MN050003-EN
www.eaton.eu
331
Design of the data bytes:
7.25.2 Read Digital Input (Object 0x30F0)
Object 0x30F0 transmits the digital value of the channels' digital signal inputs
in a double word.
Design of the data bytes:
Feature
Description / Value
EDS
Name
Output1_4
[MxSubExt20F0]
ParameterName=Output1_4
ObjectType=0x7
DataType=0x0005
AccessType=rww
PDOMapping=1
Count=1
Description
Write Digital Outputs
Object Code
VAR
Mapping
PDO
Manual
Data type
UNSIGNED8
Sub index
01 … FE
hex
Access
rww
Default value
00
hex
Byte 0:
Sub index
1
≦
n
≦
254
B7
B6
B5
B4
B3
B2
B1
B0
DO4 DO3 DO2 DO1
Feature
Description / Value
EDS
Name
Input1_4
[MxSubExt30F0]
ParameterName=Input1_4
ObjectType=0x7
DataType=0x0005
AccessType=ro
PDOMapping=1
Count=1
Description
Read Digital Input
Object Code
VAR
Mapping
PDO
Manual
Data type
UNSIGNED8
Sub index
01 … FE
hex
Access
ro
Byte 0:
Sub index
1
≦
n
≦
254
B7
B6
B5
B4
B3
B2
B1
B0
DI4
DI3
DI2
DI1