7 Product-specific CAN objects XN300 slice modules
7.26 XN-322-2SSI
Gateway XN-312-GW-CAN 06/16 MN050003-EN
www.eaton.eu
349
7.26.3 Module Diagnosis (Object 0x3101)
Object 0x3101 contains data on the channels' status.
Design of the data bytes:
Byte 0:
Feature
Description / Value
EDS
Name
ModuleDiag
[MxSubExt3101]
ParameterName=ModuleDiag
ObjectType=0x7
DataType=0x0005
AccessType=ro
PDOMapping=1
Count=1
Description
Module Diagnosis
Object Code
ARRAY
Mapping
PDO
Manual
Data type
UNSIGNED8
Sub index
01 … FE hex
Access
ro
Byte 0:
Sub index
1
≦
n
≦
254
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Data bit
Desig-
nation
Description
0
0 =
1 = Channel 1 „started“
1
0 =
1 = Channel 1 „busy“
2
0 =
1 = Channel 1 „toggle“
3
0 =
1 = Channel 1 SSI Error/ Invalid Z-Position
4
0 =
1 = Channel 2„started“
5
0 =
1 = Channel 2„busy“
6
0 =
1 = Channel 2„toggle“
7
0 =
1 = Channel 2SSI Error/ Invalid Z-Position